Screen Capture
Where this stands
No Sigma rule can address this — the telemetry MITRE names has no Sigma logsource behind it.
Sigma has no logsource taxonomy for ICS. MITRE's telemetry here is operational historians and controller state, which no Sigma rule can address.
What the technique is
Adversaries may attempt to perform screen capture of devices in the control system environment. Screenshots may be taken of workstations, HMIs, or other devices that display environment-relevant process, device, reporting, alarm, or related data. These device displays may reveal information regarding the ICS process, layout, control, and related schematics. In particular, an HMI can provide a lot of important industrial process information. Analysis of screen captures may provide the adversary with an understanding of intended operations and interactions between critical devices.
Read it on attack.mitre.orgWhat MITRE says you would watch
- AN1883
Monitor executed commands and arguments that may attempt to take screen captures of the desktop to gather information over the course of an operation. Monitoring for screen capture behavior will depend on the method used to obtain data from the operating system and write output files. Detection methods could include collecting information from unusual processes using API calls used to obtain image data, and monitoring for image files written to disk, such as CopyFromScreen, xwd, or screencapture. The data may need to be correlated with other events to identify malicious activity, depending on the legitimacy of this behavior within a given network environment.